无锡布里渊电子科技有限公司BRILLOUIN · FIBER OPTIC SENSING
主页 / 产品与应用

BOTDR1000 · 布里渊光时域反射仪

BOTDR单端接入,适合只允许从一端接入的线性资产。

BOTDR1000布里渊光时域反射仪

BOTDR1000 Brillouin Optical Time-Domain Reflectometer

BOTDR1000 · 布里渊光时域反射仪

产品原理与应用 Principle and applications

基于自发布里渊背向散射与光时域定位,采用单芯光纤、单端接入,获取沿线布里渊频移及温度或应变分布。最大配置量程60 km,典型测量时间60–300 s/通道。
Uses spontaneous Brillouin backscattering and time-domain localization. Single-core, single-ended access measures Brillouin frequency shift and temperature or strain along the fiber. Maximum configured range is 60 km; typical acquisition time is 60–300 s/channel.

布里渊频移同时受温度与轴向应变影响。测量应变时需要温度补偿,测量温度时需要消除或约束应变影响;单条频移曲线不能独立分离两个未知量。
Brillouin frequency shift responds to both temperature and axial strain. Strain measurement requires temperature compensation; temperature measurement requires strain isolation or correction. One frequency-shift trace cannot independently determine both unknown quantities.

采用光学传感与传输,抗电磁干扰;支持连续沿线测量、事件定位、光纤故障监测及长期状态管理。危险区域的光缆与整套系统按相应使用条件选配。
Optical sensing and transmission resist EMI and support continuous profiles, event location, fiber-fault monitoring and long-term condition management. Select the cable and complete system for the applicable hazardous-area conditions.

量程、空间分辨率、平均时间与测量精度存在配置关联,长距离与最高分辨率不一定同时达到。温度量程取决于传感光纤及护套;应变需通过可靠机械耦合传递至光纤。
Range, spatial resolution, averaging time and accuracy are configuration-dependent and not necessarily achieved simultaneously. Temperature range depends on the fiber and jacket; strain requires reliable mechanical transfer into the fiber.

技术参数 Technical specifications

项目 / Item规格 / Specification
系统定位误差 / System location error<1 m(对应配置与标定条件)
<1 m under the specified configuration and calibration conditions
光纤类型 / Fiber Type标准单模光纤
Standard single-mode fiber
光纤配置 / Fiber Configuration单芯光纤,单端测量
Single fiber core, single-ended measurement
测量距离 / Measurement Range5km/20km/50km/60km
测量通道 / Measurement Channels1/2/4/8
根据需要选配
Configurable as required
测量时间 / Measurement Time60~300s/通道(典型)
60-300 s/channel (typical)
测量范围 / Measurement Range(-40~+100)°C/(-10000~+10000)με
(-40 to +100) °C / (-10000 to +10000) με
测量精度 / Measurement Accuracy±1°C/±20με
±1 °C / ±20 με
测量分辨率 / Measurement Resolution0.2°C/4με
0.2 °C / 4 με
采样间隔 / Sampling Interval0.1/0.2/0.4/0.8m
采样间隔与量程按配置匹配;0.1 m适用于5 km配置
Match spacing to the configured range; 0.1 m applies to the 5 km configuration
空间分辨率 / Spatial resolution1–50 m(取决于光缆损耗与测量设置)
1–50 m (depending on cable loss and measurement settings)
报警方式 / Alarm Mode定值、差值、区域差值
Fixed threshold, differential, and zonal differential
报警分区 / Alarm Zones500分区/通道
500 zones/channel
各分区独立设置报警阈值
Alarm thresholds can be set independently for each zone
光纤接头 / Optical ConnectorFC/APC
存储空间 / Storage Capacity1TB
工作条件 / Operating Conditions−10~+50 °C;0~95% RH(无凝露)
−10 to +50 °C; 0–95% RH (non-condensing)
工作电源 / Power Supply220VAC,-48VDC(可选)
220 VAC, -48 VDC (optional)
尺寸(W×D×H) / Dimensions (W x D x H)483 × 447 × 133 mm(19英寸机架式)
483 × 447 × 133 mm (19-inch rack-mount)
重量 / Weight<15kg

产品与应用示意 Product and application views

BOTDR1000 · 布里渊光时域反射仪BOTDR1000 · 布里渊光时域反射仪

应用与相关阅读

查看全部产品规格书

与销售工程师聊聊您的项目

公司商务服务团队

公司统一服务窗口

联系我们 ↗

← 返回本站主页