BLY-SOSS-H16 · 光纤硅光解调仪
连接光纤传感头,向软件输出设备状态与感知数据。
光纤硅光解调仪
Fiber-Optic Silicon Photonic Interrogator
型号 / Model: BLY-SOSS-H16

产品概述 Product overview
16通道工业级点式硅光传感解调平台,用于加速度与声纹等传感器的采集、解调和数据通信。配合上位机或边缘计算,支持资产状态监测与预测性维护。
A 16-channel industrial point-sensor interrogation platform for acquisition, demodulation and communication of silicon photonic acceleration and acoustic sensors. Host software or edge computing supports asset condition monitoring and predictive maintenance.
支持CANopen与以太网,Profibus DP可选;标称扫描频率≥100 Hz、输出频率≥50 Hz、响应时间≤20 ms。传感头的kHz声振带宽与状态输出频率分别定义。
CANopen and Ethernet are standard, with optional Profibus DP. Specified scan rate is ≥100 Hz, output rate ≥50 Hz and response time ≤20 ms. Sensor-head acoustic/vibration bandwidth is distinct from the status-output rate.
典型应用 Typical applications
点式加速度与声纹传感;风机、汽轮机、压缩机、电机等旋转机械;高压电力设备、轨道交通和工业装备;集控平台与边缘计算系统。
Point acceleration and acoustic sensing; fans, turbines, compressors and motors; high-voltage equipment, rail transit and industrial machinery; centralized monitoring and edge-computing systems.
技术参数 Technical specifications
| Item / 项目 | Parameter / 参数 |
|---|---|
| Operating Temperature Range / 工作温度范围 | -40 °C to 65 °C |
| Storage Temperature Range / 存储温度范围 | -40 °C to 85 °C |
| Operating Humidity / 工作湿度范围 | 0 % to 95 % RH, non-condensing / 0 %~95 % RH,无凝露 |
| Corrosion Resistance / 防腐等级 | ≥ C3-H |
| Ingress Protection / 防护等级 | ≥ IP20 (standard, in-cabinet) / 柜内安装标准版 ≥ IP65 (optional high-protection outdoor version) / 柜外安装高防护版 |
| Altitude / 海拔高度 | ≤4000 m;高海拔绝缘与散热修正按适用的GB/T 20626.1及项目条件确认 ≤4000 m; confirm insulation and thermal derating against applicable GB/T 20626.1 requirements and project conditions |
| Channel Count / 通道数量 | 16 channels by default, labeled CH1 to CH16 / 默认16通道,通道编号 CH1~CH16 |
| Communication / 通讯方式 | Standard: CANopen, Ethernet / 默认:CANopen、以太网 Optional: Profibus DP / 选配:Profibus DP |
| Real-Time Output / 实时输出信号 | Device heartbeat, device status, acceleration values, range, etc. / 设备心跳、设备状态、加速度值、量程等 |
| Scan Rate / 扫描频率 | ≥ 100 Hz |
| Output Rate / 输出频率 | ≥ 50 Hz (100 Hz preferred / 优选100 Hz) |
| Response Time / 响应时间 | ≤ 20 ms |
| Supply Voltage / 供电电压 | 24 V DC (±25 %), reverse-polarity protection / 支持反接保护 |
| Power / 功率 | Rated ≤ 24 W; maximum allowable ≤ 50 W / 额定功率≤24 W;特殊情况下允许的极限功率≤50 W |
| Weight / 整机重量 | ≤ 2 kg |
| Mounting Method / 安装方式 | Bolt fixing / 螺栓固定 |
| Startup / 启停要求 | 掉电保护、参数保持、上电自启动,并自动与主控系统建立通信 Power-fail protection, parameter retention and automatic startup/communication establishment after power-up |
| Software & Data Interface / 软件与数据接口 | RJ45以太网调试维护,上位机状态监控与参数配置;出厂IP地址按设备配置表查询 RJ45 Ethernet for setup/maintenance; host status monitoring and parameter configuration. Refer to the supplied settings for the factory IP address. |
| Dimensions / 外形尺寸 | 190 × 172 × 73.5 mm(长×宽×高,最大轮廓) 190 × 172 × 73.5 mm (L × W × H, maximum envelope) |
接口与安装 Interfaces and installation

| 型号 / Model | 配置 / Configuration |
|---|---|
| BLY-SOSS-H16 | 16通道硅光解调仪 16-channel silicon photonic interrogator |
DC 24 V供电,配置可靠接地与反接保护。柜内标准版防护等级≥IP20,柜外高防护版≥IP65为选配;两者不能作为同一标配外壳等级。通过RJ45连接上位机或集控系统,多机可由工业交换机或工控机集中接入。
Use DC 24 V with reliable grounding and reverse-polarity protection. The standard in-cabinet version is ≥IP20; the ≥IP65 outdoor enclosure is optional. Connect to the host/control system via RJ45; industrial switches or PCs support multiple devices.
16通道为主机通道编号,不自动等同于16组三轴加声纹节点。三轴分量、声纹数据、同步方式及通道占用按协议和设备配置确认。额定功耗≤24 W;极限50 W为原规定的特殊条件上限,不作为持续额定功耗。
The 16 host channels do not automatically mean 16 three-axis-plus-microphone nodes. Confirm axis allocation, acoustic data, synchronization and channel use from the protocol/configuration. Rated power is ≤24 W; the specified 50 W limit applies only under the defined exceptional conditions, not continuous rated use.
传感头频响、主机扫描频率与接口输出频率分别规定。采集2 kHz或20 kHz原始波形需要足够的采样率与传输带宽;≥50 Hz状态输出不能直接等同于这些原始波形带宽,需选配并确认高速采集模式。
Sensor response, interrogator scan rate and interface output rate are separate specifications. Raw 2 kHz or 20 kHz waveforms require sufficient sampling and transport bandwidth. A ≥50 Hz status output does not establish these raw-waveform capabilities; confirm the required high-speed acquisition mode.
IP、防腐及过载指标按对应配置的试验条件使用。无源光纤的电气隔离不代替整套系统在危险区域所需的适用性验证。
Apply ingress, corrosion and overload ratings under the test conditions for the supplied configuration. Passive-fiber electrical isolation does not replace complete-system suitability verification for hazardous areas.
应用与相关阅读
与销售工程师聊聊您的项目
公司商务服务团队公司统一服务窗口
联系我们 ↗