Project background: from isolated alarms to continuous risk assessment
DTS monitoring of coal spontaneous combustion and underground cable fires addresses the long-term safety and condition management of mine goafs, sealed areas, coal bunkers, underground cables, substations, roadways and seams prone to spontaneous combustion. Such assets commonly span multiple spaces, process sections or asset identifiers; risks can move along routes, equipment boundaries and structural weaknesses rather than appearing at predetermined measuring points. Key concerns include heat accumulation from coal oxidation, air leakage, power-cable heating, dust cover, ventilation changes and restricted underground maintenance. Point sensors, manual inspections and video provide local evidence but may not capture the complete development of an anomaly from onset to response.
The solution uses DTS, centimeter-scale DTS and mining temperature-sensing cables, placing sensing fiber along the paths that need observation to create continuous, localized and replayable records. Its objective is to continuously observe coal and cable temperatures, identifying slow heating and rapid local hotspots to supplement gas monitoring with spatial location, rather than add isolated equipment. Start design with an asset-risk inventory and verifiable monitoring objectives, then specify range, spatial resolution, sampling, sensing-cable construction, software interfaces and alarms.
Risk progression and monitoring boundaries
For mine goafs, sealed areas, coal bunkers, underground cables, substations, roadways and seams prone to spontaneous combustion, distinguish initiating factors, early signs, developing conditions and consequences. Risks including heat accumulation from coal oxidation, air leakage, power-cable heating, dust cover, ventilation changes and restricted underground maintenance may occur independently or arise from combined load, environmental, construction and maintenance effects. Capture measurable changes in temperature, acoustics, vibration, strain or local condition and associate them with specific assets and distances.
Sensing principles and technology selection
A DTS interrogator launches short laser pulses into sensing fiber and calculates temperature along the fiber from returned Raman backscatter. Engineering value lies in continuous temperature profiles, accurate distance to anomalies, heating rates and heat-propagation direction rather than isolated readings. The sensing cable acts as both measurement medium and a long temperature array, without closely spaced power supplies along its route. This suits strong electromagnetic fields, damp or dusty locations, hazardous areas and sites with difficult maintenance access, subject to the required equipment and installation approvals.
The recommended combination is DTS, centimeter-scale DTS and mining temperature-sensing cables. Check monitoring distance, spatial resolution, localization accuracy, channel count, dynamic range, sampling cycle, operating temperature and communications together. Specifications should support the objective to continuously observe coal and cable temperatures, identifying slow heating and rapid local hotspots to supplement gas monitoring with spatial location, rather than be compared individually. For long routes, prioritize signal-to-noise ratio, reliable localization and far-end stability; for localized high-risk areas, assess coupling, effective sensing length and response time.

System architecture: sensing, interrogation, software and response
The system comprises sensing cable or fiber sensors, splicing and protection units, interrogation equipment for DTS, centimeter-scale DTS and mining temperature-sensing cables, edge processing, application software and supervisory interfaces. Returned signals undergo quality checks, distance calibration and parameter calculation before mapping to asset records. Outputs include live curves, time-space plots, event lists, risk zones, historical trends and reports, rather than an unexplained waveform.
Connect to mine safety, ventilation and emergency platforms for goaf zones, distance locations and trend reports. Define the data dictionary, time synchronization, alarm acknowledgment, offline buffering and recovery upload. For important projects, use tiered retention of raw or feature data to support incident reviews, algorithm improvement and threshold changes.
Sensing cable and field installation
Recommended installation: install sensing cable through boreholes, sealed walls and roadways, couple it to cable sections, and locate interrogators in safe equipment rooms with zoned optical routes. Installation quality directly affects results; the same interrogator can respond differently with different mounting, jacket materials and coupling. Design documents should identify start/end distances, slack loops, splice boxes, zone boundaries, fastening intervals, bend radius, pulling tension and protection.
Data analysis and graded alarms
The alarm model combines absolute temperature, rate of rise, differences between adjacent sections, differences between similar assets and duration. Establish normal baselines for season, load, ventilation and process state before detecting deviations. Centimeter-scale DTS suits small heat sources and dense localization, while standard and long-range DTS suit continuous routes. Select by asset size, cable coupling and permitted response time, rather than ranking systems solely by spatial resolution.
Initial application criteria: assess sustained heating alongside CO, oxygen, airflow and production conditions, using graded thresholds and trend criteria. Use advisory, early-warning, alarm and emergency levels, each with defined confirmation times, verification and actions. Calibrate thresholds against actual conditions during trial operation and record every revision, reason and effective date. Display position, asset name, measured value, baseline deviation, duration and supporting evidence together.

Commissioning, acceptance and performance verification
Acceptance should use zoned heating, controlled movement of heat sources and repeated tests under different operating conditions to verify localization error, response time, temperature repeatability and alarm interlocks. Heating a short length next to the interrogator alone is insufficient; sample the far end, joints, bends and positions with unfavorable heat transfer.
Maintenance and sustained effectiveness
Maintenance assessment should cover valid-alarm rates, confirmation time, false-alarm causes, missed-event reviews, closed work orders and detected trends, not just equipment uptime. Continued labeling of real events can improve recognition models and sustain practical performance after commissioning.
Integration with existing systems
Connect to mine safety, ventilation and emergency platforms for goaf zones, distance locations and trend reports. Let the fiber platform handle interrogation, curve analysis and original evidence, while the supervisory system manages consolidated displays, duty workflows and work orders. Depending on the project, interfaces may use Modbus TCP, OPC UA, IEC protocols, REST APIs, message queues or dry contacts. Avoid transferring only an unexplained aggregate alarm.
Every alarm on a map, plan or process diagram should link back to original curves and historical trends. Feed dispositions from supervisory systems back into event records, closing the loop between monitoring, confirmation, response, review and threshold improvement.
Benefits, operating conditions and technical boundaries
The solution replaces sampled inspections of mine goafs, sealed areas, coal bunkers, underground cables, substations, roadways and seams prone to spontaneous combustion with continuous observation, retaining traceable early indications of heat accumulation from coal oxidation, air leakage, power-cable heating, dust cover, ventilation changes and restricted underground maintenance. Passive fiber, electromagnetic immunity and multiple sensing locations on one fiber can reduce distributed power and maintenance requirements on long routes, at unattended sites or in hazardous environments. Locations and trends help teams narrow inspections, plan condition-based maintenance and prioritize risk.
Equipment selection and detailed design
Begin with five questions: which parts of mine goafs, sealed areas, coal bunkers, underground cables, substations, roadways and seams prone to spontaneous combustion require protection; which indications of heat accumulation from coal oxidation, air leakage, power-cable heating, dust cover, ventilation changes and restricted underground maintenance must be detected; what localization, response and sampling performance is needed; what routing, power, communications and cabinet facilities are available; and who confirms alarms and owns the response workflow?
Then specify the combination of DTS, centimeter-scale DTS and mining temperature-sensing cables, cable construction, single- or double-ended optical paths, channel redundancy, software licensing and interfaces. For phased projects, reserve fiber, rack space, network addresses and platform capacity. For long-distance or multisite projects, evaluate centralized interrogation, distributed edge nodes and remote maintenance together.
Application-specific validation and limitations
Access and cable survival are primary issues in goaf temperature monitoring. Installed routes may not cover all potential heat sources; collapse, crushing or later mining can damage them. Drawings should identify actual coverage and unobservable zones, rather than treating missing data as evidence of safety.
Assess spontaneous-combustion risk with ventilation, gas and mining context. DTS temperature changes provide spatial clues but cannot independently identify every oxidation stage. Separate cable-joint heating zones from goaf environmental monitoring. Check interrogator, sensing-cable and accessory suitability against actual mine requirements and product documentation.
Installation, optical-path calibration and acceptance checklist
Related products and technical resources
Explore the product categories below according to distance, spatial resolution, channels, response and site conditions. Published specifications support preliminary selection; final configuration must account for optical loss, installation and acceptance objectives.
Related equipment and specifications
Select the final model and installation to suit project conditions.
BLY-FT100
Centimeter-level distributed temperature sensing
BLY · DTS / DAS / BOTDA / BOTDR
BLY sensing cables
Related field cases
- Hangzhou Building J data-center cable monitoring
- Kunming Cable Group smart-cable monitoring
- Cable trench and cable tray monitoring