Wuxi BrillouinBRILLOUIN · FIBER OPTIC SENSING
Home / Products & applications

BOTDR1000 · Brillouin optical time-domain reflectometer

Single-ended BOTDR for linear assets accessible from one fiber end.

BOTDR1000 Brillouin Optical Time-Domain Reflectometer

BOTDR1000 Brillouin Optical Time-Domain Reflectometer

BOTDR1000 · Brillouin optical time-domain reflectometer

Principle and applications

Uses spontaneous Brillouin backscattering and time-domain localization. Single-core, single-ended access measures Brillouin frequency shift and temperature or strain along the fiber. Maximum configured range is 60 km; typical acquisition time is 60–300 s/channel.

Brillouin frequency shift responds to both temperature and axial strain. Strain measurement requires temperature compensation; temperature measurement requires strain isolation or correction. One frequency-shift trace cannot independently determine both unknown quantities.

Optical sensing and transmission resist EMI and support continuous profiles, event location, fiber-fault monitoring and long-term condition management. Select the cable and complete system for the applicable hazardous-area conditions.

Range, spatial resolution, averaging time and accuracy are configuration-dependent and not necessarily achieved simultaneously. Temperature range depends on the fiber and jacket; strain requires reliable mechanical transfer into the fiber.

Technical specifications

ItemSpecification
System location error<1 m under the specified configuration and calibration conditions
Fiber TypeStandard single-mode fiber
Fiber ConfigurationSingle fiber core, single-ended measurement
Measurement Range5km/20km/50km/60km
Measurement Channels1/2/4/8
Configurable as required
Measurement Time60-300 s/channel (typical)
Measurement Range(-40~+100)°C/(-10000~+10000)με
(-40 to +100) °C / (-10000 to +10000) με
Measurement Accuracy±1°C/±20με
±1 °C / ±20 με
Measurement Resolution0.2°C/4με
0.2 °C / 4 με
Sampling Interval0.1/0.2/0.4/0.8m
Match spacing to the configured range; 0.1 m applies to the 5 km configuration
Spatial resolution1–50 m (depending on cable loss and measurement settings)
Alarm ModeFixed threshold, differential, and zonal differential
Alarm Zones500 zones/channel
Alarm thresholds can be set independently for each zone
Optical ConnectorFC/APC
Storage Capacity1TB
Operating Conditions−10 to +50 °C; 0–95% RH (non-condensing)
Power Supply220 VAC, -48 VDC (optional)
Dimensions (W x D x H)483 × 447 × 133 mm (19-inch rack-mount)
Weight<15kg